Installation Tier Overview

See table below for descriptions of device installation tiers. 

Tiers are to be taken into consideration when conducting Site Surveys and when entering information in Sensor Notes during installation. 

All ceiling heights are Above Finished Ceiling (AFF)

 

  L302 E106 EN-1 G400 Gateway
Tier 1

Magnetic
Ceiling height 8-12’


Attach sensor with pre-installed magnets to metal surface t-bar, strut or others. 

N/A N/A N/A
Tier 2

Non-Magnetic
Ceiling height 8-12’ 


Non-ferromagnetic surface (aluminum, drywall, concrete, wood, ceiling tile, gypsum, or fabric/felt)


Mount sensor plate with included screws


Mount sensor with magnets

Direct to ceiling
Ceiling height 8-12’ 

 

Mount standard bracket with screws shipped with sensors


Drill hole for ethernet cable.

Direct to ceiling
Ceiling height 8’ – 19’ 


Mount standard bracket with screws shipped with sensors


Drill hole for ethernet cable.

Direct to ceiling
Ceiling height 8-12’ 


Mount standard bracket with screws shipped with sensors


Drill hole for ethernet cable.

Tier 3

Special scenarios
Phone / Privacy booths/ Windows / Aluminum panels / Exposed ducts & beams


Use of VergeSense adhesive or Tier 3 Magnetic kits.

Direct to Wall
Wall height 8-12’ 


Install wall bracket with provided screws.


Drill hole for ethernet cable
Insert standard mounting bracket into wall bracket.


Mount sensor on standard mounting bracket

Direct to Wall
Wall height 8’ – 19’


Corner Bracket, 10" x 10" x 1-1/4"


Corner bracket installed on wall to mount EN-1 to.

Direct to Wall
Wall height 8-12’ f


Install wall bracket with provided screws


Drill hole for ethernet cable
Insert standard mounting bracket into wall bracket.
Mount sensor on standard mounting bracket

Tier 4

Drop rod
Threaded rod to bring sensor 8-12’


Mount the sensor plate to the rod


Mount sensor to the flat plate with pre-installed magnets

Drop rod
Threaded rod to bring sensor 8-12’ 


Mount the sensor plate to the rod

Drop rod
Threaded rod to bring sensor 8’ – 19’ 


Mounting with the drop rod adapter, ships with sensor if requested.


Mount rod adapter to standard sensor bracket.

Drop rod
Threaded rod to bring sensor 8-12’ 


Mount the sensor plate to the rod

 